Parts of an injection mold and how to identify a replacement component
Back to News

Published on

Parts of an injection mold and how to identify a replacement component

Use the mold drawing and the stage of the cycle to identify a component. Follow the melt path and cooling circuit, then check which parts guide the mold, control opening and release the molded part.

Where the plastic goes and where the water goes

The cavity and core form opposite surfaces of the part. In a cold-runner mold, melt travels through the sprue and runner and enters the cavity through a gate. The drilled cooling channels carry a separate fluid. When a drawing calls for a manifold, trace its connections: a hot-runner manifold conveys melt, while a cooling water manifold connects the water circuits. A TL4-44 water manifold has four inlets and four outlets.

Double-row aluminum water manifold for injection mold cooling

What locates the halves and controls opening

Guide pins and bushings guide the two halves together. A precision interlock provides local alignment at closing. A nylon-sleeve parting lock helps control which parting surface opens first. For a replacement sleeve, measure its outside diameter: the Ø12 and Ø13 versions in the drawing both use an M6 screw and are 20 mm long.

To identify the part that holds a slide in its retracted position, compare the slide retainer and its mating pin.

Which parts release the molding

An ejector plate moves the ejector pins to push the molding off the core. On a part that holds a vacuum, a mold air poppet valve admits air at release. For the valve, compare body diameter, housing diameter and mounting depth. When checking a die spring, record its free length, installed length and additional working stroke so the supplier can check the load at each end of travel.

T-US-pattern mold air poppet valve

What stays on the part and what stays on the tool

A mold date stamp insert leaves a mark on the molded part. A mechanical cycle counter records the tool’s cycles for maintenance. For a date insert, photograph the marking face and measure the outer ring and inner insert separately. For a counter, show the actuator direction and screw pattern in a side view of the tool.